real time.
3. Indicates the earliest error when history records of errors (F007) are displayed.
1. Indicates a data display format when parameters are displayed and adjusted in real time. If it is
on, it indicates the data is displayed in hexadecimal; otherwise it indicates the data is displayed
in decimal.
2. Indicates the latest error when the history records of errors (F007) are displayed.
1. If it is on, it indicates that internal data is currently displayed.
2. If it flickers, it indicates that the power part of the driver is in the working status.
MODE
1. Switches basic menus.
2. During the adjustment of parameters, short presses the key to move the bit to be adjusted, and
long presses the key to return to the previous state.
Presses ▲ to increase set values; long presses ▲ to increase numbers promptly.
Presses ▼ to decrease set values; long presses ▼ to decrease numbers promptly.
ENTER
1. Enters the selected menu by pressing this key.
2. Keeps current parameters in the enabled status.
3. Confirms input parameters after parameters are set.
4. Long presses this key to switch to higher/lower 16 bits when internal 32-bit data is displayed in
real time.
P..L
Activates position positive limit signals.
n..L
Activates position negative limit signals.
Pn.L
Activates position positive/negative limit signals.
Overall
Flicking
Indicates that an error occurs on the driver, and is in the alarm state.
If the parameter adjusting display mode is featured by the decimal system:
When the units place is flickering, press to add 1 to the current value; press to deduct 1 from the
current value. When the tens place is flickering, press to add 10 to the current value; press to deduct 10
from the current value. When the hundreds place is flickering, press ▲ to add 100 to the current value; press ▼
to deduct 100 from the current value. When the thousands place is flickering, press ▲ to add 1000 to the current
value; press ▼ to deduct 1000 from the current value.
If the parameter adjusting display mode is featured by the hexadecimal system:
When the units place is flickering, press to add 1 to the current value; press to deduct 1 from the
current value. When the tens place is flickering, press to add 0X10 to the current value; press to deduct
0X10 from the current value. When the hundreds place is flickering, press ▲ to add 0X100 to the current value;
press ▼ to deduct 0X100 from the current value. When the thousands place is flickering, press ▲ to add 0X1000
to the current value; press ▼ to deduct 0X1000 from the current value.
When adjusting decimal parameters, the display mode is automatically switched to the hexadecimal system
if the data is greater than 9999 or less than -9999. In this case, the 3
rd
decimal point from left to right is
highlighted.