45
0
360 V
Note:Factory parameters
adjust
d5.11
60F6061
0
Comm_Shift_UVW
Indicates the excitation pointer of a motor
Note:Factory parameters
N/A
Please dont
adjust
d5.12
2600001
0
Error_Mask
Indicates error masks
Note:Factory parameters
FFF.F
Please dont
adjust
d5.13
60F7051
0
RELAY_Time
Indicates the relay operating time of
capacitor short-circuits
Unit: mS
Note:Factory parameters
150
d5.14
2FF0040
8
Key_Address_F00
1
Sets numeric display data
N/A
d5.15
65100B1
0
RS232_Loop_Ena
ble
01 to 1. 11 to N
0
d5.16
2FFD001
0
User_Secret
User password.16bits.
0
65535
d5.17
2F81000
8
CAN_Baudrate
CAN baudrate setting
100:1M 50:500K
25:250K 12:125K
5:50K 1:10K
50
Need save
and restart
d5.18
2FE2001
0
RS485_Baudrate
Baudrate of RS485
1080: 9600
540: 19200
270: 38400
90: 115200
540
Need save
and restart
d5.19
65100C0
8
RS485_Protocol
RS485 communication protocol select
0: Modbus
1: Same protocol as RS232
1
Need save
and restart

Table of Contents