SANARIUM B, S
PAGE 59
50701206/02.18
12. Cleaning and maintenance
12.3. SANARIUM B - Decalcifying the evaporator
SANARIUM B - Draining
1. Place the filler can (1) under the drain. Open
the drain valve (2).
2. Close the drain valve (2) again after draining
the evaporator.
3. Drain the filler can (1).
open close
1
2
3
2
3
SANARIUM B - Decalcifying
4. Fill the filler can (1) with approximately 4 litres
of water.
Risk of chemical burns
There is a risk of chemical burns to
eyes and skin when handling
decalcifiers.
Always follow the instructions on the
package insert.
5. Add the decalcifier.
. Note the quantity listed on the package
insert.
6. Use the filler can (1) to fill the evaporator's
filling unit (3).
. Allow the decalcifier to act overnight, or
follow the timings indicated on the package
insert.
7. Place the filler can (1) under the drain. Open
the drain valve (2). Drain water into the filler
can (1).
SANARIUM B - Rinsing
8. Close the drain valve (2).
9. Fill the evaporator's filling unit (3) with water.
10. Place the filler can (1) under the drain. Open
the drain valve (2).
11. Close the drain valve (2) again after draining
the evaporator.
12. Repeat the rinsing procedure two or three
times.
Resetting error 92 on the control panel
. The final drying phase must have finished.
13. In standby mode clear the fault by pressing
the symbol 92.