[Direct access: CMD -> 7084]
Parameter
[Direct access]
Definition of an output signalling the active
standby mode.
Selection whether the inputs for the standby
mode signal are applied by normally close
contacts or normally open contacts.
Definition of a time in seconds when the standby
mode is to be activated.
Definition of the maximum delay time (in
seconds) for which, after switched back to
normal operation from standby, the installation
has to wait for a report about whether VVVF is
ready. Should no ready message be received in
this time, a controller error will be registered
and the lift will go out of operation.
Definition of an input to switch off the standby
mode.
Definition of an input to switch on the standby
mode.
Definition of an input which signals the ready
state (after standby) of the inverter to the
controller.