141
MA06-03-1-01
Menu
In case of an earthquake there will appear a status report on the hand terminal in order to narrow
down the possible causes.
Here, the following correspondence applies:
1=Activation by vertical/seismics-warning
2=Activation by horizontal
3=Activation by counterweight/seismics-activated
[Direct access: CMD -> 7211]
Parameter
[Direct access]
Description
Default
value
Value
Range
I:Horizontal
Definition of an input for the detection of an
earthquake case by means of the monitoring of
the horizontal vibration. In this case, the lift is
set to continue traveling until next landing,
where it stops.
I:Vertical
Definition of an input for the detection of an
earthquake case by means of the monitoring of
the vertical vibration. In this case, an evacuation
run to the next landing will be initiated.
.
I:Counterweight
Definition of an input for the detection of an
earthquake case by means of the monitoring of
the counterweight. In this case, an evacuation
run to the next landing will be initiated insuch a
direction to ensure the lift is moving away from
the counterweight.