149
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value
Range
Note: The following parameters must
maintain their default value and not be
modified.
❑ Τ: Door open time (s) = 15
[Parameters → Doors → Door
times → T: Door open time (s)]
❑ Τ: Stay time car calls (s) = 3
[Parameters → Doors → Door
times → T: Stay time car calls (s)]
T:Stop in main landing (s)
Dwell time in the main landing during
which the landing doors remain open –
measure in seconds. Afterwards, door
closing time follows.
240
T:Stop Sabbath mode (s)
Sabbath-function ending time in seconds.
During this interval, the illuminated display
blinks again.
30
COP active
By choosing YES, it is possible to set calls at
the lift’s car push-buttons. For a detailed
procedure see description above.
NO
YES/NO