157
MA06-03-1-01
Menu
[Direct access: CMD -> 7164 -> 7165]
Parameter
[Direct access]
Description
Default
value
Value Range
Max. operating hours
OHC
Entry of the maximum value of the lift
operating hours. When this value is
exceeded, the lift is switched to “out
of order” mode. Entering value 0
deactivates this function.
OHC message after (%%)
Entry of a percentage, which after
being exceeded initiates a
maintenance notification to be put
out.
90
(in %)
Out of order OHC
Query whether the lift is to be put out
of order effectively or whether it is
only to be displayed.
YES/NO
Max. travel counter (TRC)
Entry of the maximum value of the lift
travels. When this value is exceeded,
the lift is switched to “out of order”
mode. Entering value 0 deactivates
this function.
TRC Message after (%%)
Entry of a percentage, which after
being exceeded initiates a
maintenance notification to be put
out.
90
(in %)
Out of order TRC
Query whether the lift is to be put out
of order effectively or whether it is
only to be displayed when exceeding
the maximum TRC value.
YES/NO