201
MA06-03-1-01
Menu
Long text
Brake 1 not opened!
Description
3 seconds upon termination of travel, the controller checks whether the brakes are opened. That is, in
case of an error, the input brake1 is still applied.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- activation of the brake does not function properly (refer to wiring diagram)
- brake shoe contact is not set up correctly
- wiring is not correct
- Brake MCB (FBR)
- defective input
Remedy
- See causes
- Check input on the status page
If the input should be defective it can be parameterized to another available I/O any time.
Error code : 44
Reset
800 + Ok / Recall
Short text
Brake 1 not closed!
Long text
Brake 1 not closed!
Description
3 seconds upon termination of travel, the controller checks whether the brakes are closed. That is, in
case of an error, the input brake1 is not applied.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- activation of the brake does not function properly (refer to wiring diagram)
- brake shoe contact is not set up correctly
- wiring is not correct
- defective input
Remedy
- See causes
- Check input on the status page
If the input should be defective it can be parameterized to another available I/O any time.
Error code : 45
Reset
800 + Ok / Recall
Short text
Brake 2 not opened!
Long text
Brake 2 not opened!
Description
3 seconds upon termination of travel, the controller checks whether the brakes are opened. That is, in
case of an error, the input brake2 still applies.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- activation of the brake does not function properly (refer to wiring diagram)
- brake shoe contact is not set up correctly
- wiring is not correct
- Brake MCB (FBR)
- defective input
Remedy
- See causes
- Check input on the status page
If the input should be defective it can be parameterized to another available I/O any time.
Error code : 46
Reset
800 + Ok / Recall
Short text
Brake 2 not closed!
Long text
Brake 2 not closed!