3 seconds upon termination of travel, the controller checks whether the brakes are opened. That is, in
case of an error, the input brake1 is still applied.
The controller switches into “out-of-order” mode.
- activation of the brake does not function properly (refer to wiring diagram)
- brake shoe contact is not set up correctly
- wiring is not correct
- Brake MCB (FBR)
- defective input
- See causes
- Check input on the status page
If the input should be defective it can be parameterized to another available I/O any time.
3 seconds upon termination of travel, the controller checks whether the brakes are closed. That is, in
case of an error, the input brake1 is not applied.
The controller switches into “out-of-order” mode.
- activation of the brake does not function properly (refer to wiring diagram)
- brake shoe contact is not set up correctly
- wiring is not correct
- defective input
- See causes
- Check input on the status page
If the input should be defective it can be parameterized to another available I/O any time.
3 seconds upon termination of travel, the controller checks whether the brakes are opened. That is, in
case of an error, the input brake2 still applies.
The controller switches into “out-of-order” mode.
- activation of the brake does not function properly (refer to wiring diagram)
- brake shoe contact is not set up correctly
- wiring is not correct
- Brake MCB (FBR)
- defective input
- See causes
- Check input on the status page
If the input should be defective it can be parameterized to another available I/O any time.