200
MA06-03-1-01
Menu
- Check output test seismic and input seismic mode
Error code : 40
Reset
800 + Ok
Short text
ACCU Error
Long text
ACCU-Control Error
Description
The lead-battery which is mounted to the controller is either defective or not connected (is only checked
in standstill)
Reaction
General
The controller switches into “out-of-order” mode.
Rope
The lift stops in the current landing
Hydraulic
The lift descends into the lowest landing
Causes
- battery disconnected
- defective battery
Remedy
- See causes
If the battery should be defective, one deactivates the monitoring via the menu Tools ->
Adjustment -> Surveillance -> Battery control j/n”
We highly URGE you to note that the battery needs to be replaced both at your installation and
in the maintenance book.
Error Code: 41
Reset
800+Ok
Short text
Brake error
Long text
Brake error
Description
This error code indicates that there has been a brake error prior to reset or restart.
Reaction
General
The control switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- A brake error that existed prior to shut-down/reset was saved
Remedy
- Remove the brake error as indicated under error code 43-46 and reset with 800+OK
Error code : 42
Reset
Automatic
Short text
Phase Error
Long text
Phase Error
Description
The integrated phase sequence detects a phase failure or a wrong direction of rotation.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
The lift stops in the current landing
Hydraulic
The lift descends into the lowest landing
Causes
- Phase failure in the mains
- Phases are not clamped correctly L1/L2/L3
- Defective fuse in the controller/allocation
Remedy
- See causes
If the phase sequence monitoring is not needed, one can deactivate the monitoring via the
menu “Tools -> Adjustment -> Surveillance -> Phase control j/n”
We highly URGE you to note this circumstance both at your installation and in the maintenance
book.
Error code : 43
Reset
800 + Ok / Recall
Short text
Brake 1 not opened!