27
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value
Range
t:v0 off->dir. off (ms)
Time elapsing between switch-off of the v0
speed signal (approaching speed) and the
direction signal. It corresponds to the time
provided to the inverter for an electrically
controlled stop.
500
0-
2000ms
t:v0 off->HS off (ms)
Time elapsing between switch-off of the v0
speed signal (approaching speed) and the
main contactors. It corresponds to the time
provided to the inverter for switching off the
brake.
4000
0-
2000ms
[Direct access: CMD -> 7034]