EasyManua.ls Logo

Kleemann GENIUS20 - Page 40

Default Icon
233 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
MA06-03-1-01
Menu
[Direct access: CMD -> 7109]
Parameter
[Direct access]
Description
Default
value
Value Range
T:Car light off (s)
Time in seconds after which the car light is
switched off. The initial point is the last
completed door movement. Setting the
value to 0 does not effect an automatic
deactivation.
60
0-9999 s
T:Display off (s)
Time in seconds after which the display on
the bus are switched off. The initial point is
the last completed door movement.
Setting the value to 0 does not
automatically shut-down the displays
(deactivation).
0
0-9999 s
T:HT_Display off (s)
In order to save electricity the hand-
terminal display dims after the pre-set time
interval (in seconds) elapses.
Here, setting the value to 0 deactivates the
shutting-down process (dimming) of the
display.
0
0-9999 s
Light off with open
door?
Defines whether the car lights are switched
off when the lift parks with open doors. A
power loss will result to the re- activation
of the car lights.
YES/NO