[Direct access: CMD -> 7035]
Parameter
[Direct access]
Delay time of quick start when its activation is conducted
be the door-closing signalof the controller. By setting the
value 0, quick start may only be activated by the input
“Quick start” which is described below.
Input which initiates the quick start. Generally, this is a
magnetic switch which is enabled during the last third of
the door’s closing movement. As a consequence, the
main contactors as well as the inverter with direction and
“zero speed” are activated. Thereby, the drive is already
magnetized without initiating a car movement yet.
This output transmits the ‘zero speed’ to the inverter.
When disabling the output, the inverter is being
transferred the required speed for travelling. Depending
on the type of inverter used in the installation, the target
speed might already be available along with the zero
speed; thus merely requiring the latter to be switched
off.