48
MA06-03-1-01
Menu
[Direct access: CMD -> 7028->7082]
Parameter
[Direct access]
Description
Default
value
Value Range
I:Car light sensor
Setting an input for the monitoring of the car light
via an external sensor.
Battery control
Query whether the battery is to be monitored.
NO
YES/NO
Step Err(in %)
Determine at which percentage of travels with
registered step errors the user wishes an error
message to be issued to the control centre.
1
0-100%
Step Threshold
(mm)
Setting a threshold at which a step error is
detected.
25
1-49mm
O:Step Error is
detected
Determine an output for reporting the error
message of a step error.
Doors monitor
Query whether the interlocking contacts need to
be checked for opening in the case of both open
car doors as well as open shaft doors.
YES
YES/NO
t:delay to set
S6(ms)
Waiting time until contacts switch and the test is
conducted. When this value is set to 0, the testing
of the door contact is activated by means of the
door-open limit switch.
1500
0-9999 ms
O: Alarm Filtering
Determine an output for filtering an emergency
call (prevention of misuse) while traveling.