[Direct access: CMD -> 7029]
Parameter
[Direct access]
The travel monitoring time defines the time
interval between the beginning of the car
movement and standstill. If the set time
frame elapses before the target landing has
been approached, a corresponding ‘travel
monitoring time’ error message will be
issued.
Definition of rated speed in mm/s.
This speed is the lift’s normal fast travelling
speed.
Definition of maximum speed in mm/s.
This parameter describes the car’s
maximum applicable speed and is computed
based on the nominal speed plus additional
10 %.
If this value is exceeded, the lift stops and
the message ‘maximum speed exceeded’ is
displayed. Entering value 0 deactivates the
speed monitoring.
Distance between highest landing and upper
final limit switch in mm. If after having
covered the above indicated distance the
final limit switch cannot be reached yet
(while e.g. “moving to final limit switch”),
the following error message is indicated:
“final switch not reached”.
Note: At any rate, the set value needs to be
somewhat larger than the distance between
the highest landing and final limit switch