EasyManua.ls Logo

Kleemann GENIUS20 - Page 49

Default Icon
233 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
MA06-03-1-01
Menu
[Direct access: CMD -> 7029]
Parameter
[Direct access]
Description
Default
value
Value Range
T: Travel timer (s)
The travel monitoring time defines the time
interval between the beginning of the car
movement and standstill. If the set time
frame elapses before the target landing has
been approached, a corresponding ‘travel
monitoring time’ error message will be
issued.
45 s (EN 81
requirement)
0-180 s
Nominal speed
(mm/s)
Definition of rated speed in mm/s.
This speed is the lift’s normal fast travelling
speed.
1600
0-9999
mm/s
Maximum speed
(mm/s)
Definition of maximum speed in mm/s.
This parameter describes the car’s
maximum applicable speed and is computed
based on the nominal speed plus additional
10 %.
If this value is exceeded, the lift stops and
the message ‘maximum speed exceeded’ is
displayed. Entering value 0 deactivates the
speed monitoring.
1600 + 10% =
1760
0-9999
mm/s
Final switch up (mm)
Distance between highest landing and upper
final limit switch in mm. If after having
covered the above indicated distance the
final limit switch cannot be reached yet
(while e.g. “moving to final limit switch”),
the following error message is indicated:
“final switch not reached”.
Note: At any rate, the set value needs to be
somewhat larger than the distance between
the highest landing and final limit switch
100
999 mm