Page #66 background imageLoading...
Page #66 background image
66
MA06-03-1-01
Menu
[Direct access: CMD -> 7117]
Parameter
[Direct access]
Description
Default
value
Value Range
I:Door 1 open button
Definition of the input for the door open
button on door side 1.
C.54.1
I:Door 2 open button
Definition of the input for the door open
button on door side 2.
Door open: Allow
Query whether the door opening function
is to be carried out based on the door
opening permission.
NO
YES/NO
Door open: car-mask
Query whether the door opening function
is to be carried out based on the current
door mask.
NO
YES/NO
Door open: all-mask
Query whether the door opening function
is to be carried out based on all door
masks.
NO
YES/NO
Door open: always
Query whether the door opening function
is to be always executed.
YES
YES/NO