Page #92 background imageLoading...
Page #92 background image
92
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value
Range
O: Alarm Filtering
Determination of an output to suppress the
emergency call (alarm filtering).
O:Level
Determination of an output to signal the "level"
state. The message is sent if the car is within the
zone.
O:Overspeed gov. car
test
Determination of an output to activate the
governor coil.
O:Overspeed gov. cw
test
Determination of an output to activate the
counterweight limiter.
O: Reset overspeed
gov.
Determination of an output to reset the speed
limiter.
O:Door bridging
Determination of an output to activate the
bridging of door contacts.
O: Recall
Determination of an output to signal that the
recall mode has been activated.
O: 3Phase fault
Determination of an output to signal that there
is a phase error (wrong phase direction or
missing phase).
t:delay (ms)
Delay time which elapses between the
occurance of a phase error until its recognition
as such. The phase monitoring operates
independently from whether an output for
phase error is programmed.
0
0-9999
ms
O:Out of order 1
Definition of the first output to signal the out-of-
order state.
O:Out of order 2
Definition of the second output to signal the out-
of-order state.
O:Out of order 3
Definition of the third output to signal the out-
of-order state.
O:Shaft VO
Determination of an output to signal that the
upper prefinal switch is activated.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kleemann GENIUS20 and is the answer not in the manual?

Kleemann GENIUS20 Specifications

General IconGeneral
BrandKleemann
ModelGENIUS20
CategoryController
LanguageEnglish