MA06-03-1-01
Menu
With transfer-IO it is possible to transmit signals between controller, car or landing without using
additional travelling cable cores.
Using the transfer I/Os 1-6, one individual transfer I/O can be determined; the parameter 1.I:Transfer
serves to determine the first I/O of any number of consecutive transfer I/Os. In this process, I/Os with
addresses less than 48 on the landing bus are created with one I/O each on the bus module. In case of
addresses greater than 48, the I/Os are arranged in a directly consecutive series. The parameter
L.I:Transfer serves to determine the last I/O of the sequence.
[Direct access: CMD -> 7193 -> 7194]
Parameter
[Direct access]
Description
Default
value
Value Range
I: Transfer 1
Definition of an input that is to be
transferred to the corresponding output.
O: Transfer 1
Definition of the output to which, the
above-mentioned input is transferred.
1. I: Transfer
Definition of the first input that is to be
transferred to the corresponding output.
L. I: Transfer
Determine the last input of a series of
consecutive transfer I/Os.
1. O: Transfer
Definition of the first output to which, the
above-mentioned input is transferred.