Page #95 background imageLoading...
Page #95 background image
95
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value
Range
O: Inspection 1
Definition of an output for signalling an active
inspection run.
O: Inspection 2
Definition of a second output for signalling an
active inspection run.
O: Inspection 3
Definition of a third output for signalling an
active inspection run.
O: Travel counter
Definition of an output for travel counter
indication. Under the menu item “Special”
“Maintenance interval” the settings for travel
counting are parameterized.
O: Travel counter up
Definition of a pulse output for travel counter
indication in upwards direction. Under the menu
item “Special” “Maintenance interval” the
settings for travel counting are parameterized.
O: Travel counter
down
Definition of a pulse output for travel counter
indication in downwards direction. Under the
menu item “Special” “Maintenance interval”
the settings for travel counting are
parameterized.
O: Position > H1
Definition of an output indicating that the car is
above the programmed height H1. This output
may be used for various purposes e.g. Switching
on a light.
Height H1 (mm)
Definition of the height H1.
0-999999
mm
O: Position < H2
Definition of an output indicating that the car is
lower than the programmed height H2.
Height H2 (mm)
Definition of the height H2.
0-999999
mm
O: Motor fan
Address- output via which the motor fan
(preselection relay) is enabled.
T:Fan overrun time (s)
Overrun time of the motor fan in sec.
3
0-9999 s