EasyManua.ls Logo

Klereo Kompact - Connecting Klereo Salt to Klereo Kompact; Connecting K-Link Communication Bus Line

Klereo Kompact
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Klereo Kompact installation manual V 3
22
4.7.2 Connecting Klereo Salt to Klereo kompact
Figure 34. Connecting Klereo Salt power supply
Make an electrical connection between R-RN terminals on Klereo Kompact control box unit
and N-L terminals on Klereo Salt control box unit.
4.7.3 Connecting K-link communication bus line
Figure 35. Connecting K-link communication bus
Connect K-link bus lines of both control box units while matching the B+, lin and B- wirings.
Klereo Salt circuit board is inside Klereo Salt control box unit.
Once the wiring is done and when starting-up, if the following message appears: Match
Chlorinator, it means that Klereo Salt is not matched with Klereo Kompact. If so, proceed as
follows:
1. Press the orange matching key button on the Klereo Salt circuit board (as shown on
diagram 35) until the matching LED 2 flashes rapidly,
2. Release the key button
3. Press briefly the orange matching key button (as shown on picture 35) on the
Klereo Kompact circuit board till the matching LED flashes rapidly.
R-RN terminals N-L terminals
Klereo Salt control box unit
Klereo Kompact control box unit
Klereo Salt circuit board
Klereo Kompact circuit board
Orange
matching
key button
LED 2
Matching
LED

Table of Contents