This double relay output can also be set up to pilot a metering pump for flocculant or another
auxiliary equipment (Aux B) (refer to §5.12: outputs assignment).
Kompact is equipped with 4 inputs:
1 – The A and B input is used to indicate if pool cover status: open or closed.
2 – The C and D input is used to detect the empty disinfectant tank (liquid Chlorine or active
Oxygen)
3 – The E and F input is used to detect the empty pH tank.
4 – The I and J input is supplied in 220V. It allows a remote control of lighting or filtration
outside Klereo in a slave mode (refer to § 5.16: inputs set-up)
Chart 1. Klereo Kompact Inputs / outputs chart (default set-up)
Inputs/outputs Functions Connectors Types Max amperage
Couv. input Pool cover input A B Dry contact NA
Bidon Trait input
Disinfectant tank
input
C D Dry contact NA
Bidon pH input pH tank input E F Dry contact NA
220V input 220 V input I J
Live
neutral
NA
Filtra output Filtering output V1 V2 Dry contact 10A
Aux A output Auxiliary A output P Q Dry contact 10A
pH output pH output S SN
Live
neutral
2,5A
Desinf. output Disinfectant output R RN
Live
neutral
2,5A
Aux B output
Flocculant or other
auxiliary
K KN
Live
neutral
2,5A
Lighting or other
auxiliary
M1 M2 Dry contact 8A
4.4 Connecting filtering
The filtering output (V1 V2) must be connected to the electrical circuit supplying the filtering
pump. This output is a normally open contact. The power supply going through should not
exceed 10A. Make sure that the electrical circuit is equipped with necessary protections
meeting local standards.
IMPORTANT
Never connect the filter pump directly to Klereo Kompact control box unit
V1-V2 inputs.
Set the filtering switch in Auto mode