Strainer
Transparent flexible pipe
Remove the strainer nut
Insert the pipe into the nut
Insert the transparent flexible pipe
onto the strainer
Screw the nut (put Teflon tape to seal)
Figure 17. Mounting the drawing strainer
3.7 Installing the water treatment tanks and injections
IMPORTANT:
Never mix the chemical products. Use normal protective wear (gloves, face mask and
eye protectors) to handle tanks of chemical products.
Check that the holding collars used to inject the products are sealed. The room must
be ventilated. Keep a minimum distance of 1 m between the tanks and the Klereo
components, to avoid fumes from the products damaging the system.
When changing a tank, handle carefully the tube or the cane. Do not force on the
strainer and the empty tank level detector at the end of the cane (when using a
drawing cane with empty tank level detector: optional).
Use sodium hypochlorite in liquid form as disinfectant, sulfuric acid to reduce pH
and caustic soda (sodium hydroxide) to increase pH.
When making installation or when replacing a tank, check that the chlorine injection
pump is connected to the liquid chlorine tank, and the same for the pH reduction or
pH increase product injection pump.
Put each tank into a drip tub to avoid mixing chemical products in case of leaks.