SECTION 1
INTRODUCTION
Jan 2001
Page 1-14
05114566
1.4.4 Emergency Medical Treatment
An information card to aid treating a waterjet injury is included in the binder of
each manual. The card is shown below. Contact the address shown for
additional cards.
(Front Side)
Medical Alert
This card is to be carried by personnel working with high pressure
Waterjet equipment. Obtain medical treatment
immediately for ANY high pressure waterjet injuries.
KMT WATERJET SYSTEMS
635 West. 12
th
Street
Baxter Springs, KS. 66713
(620) 856-2151
(Back Side)
This person has been working with water jetting at pressures to
55,000 psi (374MPa, 3740 bar, 3867 Kg/cm
2
) with a jet velocity
of 3,000 fps (914 mps). Foreign material (sand) may have been
injected with water. Unusual infections with microaerophilic
organisms occurring at lower temperatures have been reported,
such as gram negative pathogens as are found in sewage.
Bacterial swabs and blood cultures may therefore be helpful.
This injury must be treated as an acute surgical emergency and
be evaluated by a qualified surgeon. Circulation may be
compromised, therefore, DO NOT APPLY HEAT TO
INJURED PART. For first aid: (1) Elevate injured part (2)
Antibiotics (3) Keep injured person NPO.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KMT STREAMLINE SL-IV 100 and is the answer not in the manual?

KMT STREAMLINE SL-IV 100 Specifications

General IconGeneral
BrandKMT
ModelSTREAMLINE SL-IV 100
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals