SECTION 6
LOW PRESSURE WATER
Jan 2001
Page 6-1
05114616
6 Low Pressure Water System
The SL-IV100hp Waterjet Pump is equipped with two low pressure circuits:
Cutting water supply for HP intensifier assembly
Cooling water supply for the oil-to-water heat exchanger
The low pressure water system supplies the pump with the following:
Water of sufficient cleanliness and pressure to the inlets of the four (4) HP
cylinders (both hydraulic intensifiers)
Cooling water of sufficient flow rate and low temperature to the oil-to-water
heat exchanger.
6.1 Oil Cooling Water Supply
The oil cooling water supply circuit includes the water modulating valve.
The maximum flow rate of the cooling water is 4.5 gpm (40 psi min inlet
pressure, at 70
0
Fahrenheit maximum inlet temperature) with drain or outflow
of same capacity.