SECTION 3
OPERATION
Nov 2002
Page 3-6
05114582
3.3.1 Initial Pump Start Up Checks
The following checklist should be reviewed before turning on the unit.
• Verify all interface connections have been made.
• Verify all safety circuits are connected and operational.
• Make sure the oil tank (1) is full, check the sight glass (2) located on the side
of the tank. If oil is needed, remove cap (4) and pump oil through fill port
(3).
• Insure all cooling water valves, supply water valves, and high pressure
valves are open.
• Check direction of motor rotation arrow (5).
Motor direction of rotation should be checked any time
electrical maintenance/modification is performed on the
motor starter wiring or on the service wiring to the pump.
Failure to verify correct motor rotation can result in costly
damage to the hydraulic pump.
CAUTION
!