SECTION 3
OPERATION
Nov 2002
Page 3-14
05114582
3.5.6 Cutting Water Supply
F3 is the toggle for the cutting water supply. With F3 turned ON, cutting water
supply automatically shuts off, five (5) minutes after the electric motor is shut off. The
cutting water supply must be reset by pushing F6 before the motor will start. With F3
selected in the OFF mode, cutting water pressure will continue to be available to the
pump, even if the electric motor is not running.
3.5.7 Idle Shutdown
F4 is the toggle for the idle Shutdown. With F4 selected ON the pump will
automatically shut down after thirty (30) minutes of running idle. With F4 toggled
OFF, the pump will continue to run indefinitely.
3.5.8 High Pressure Water Transducer
The high-pressure water transducer provides a display of the operating
pressure to the nearest 1000 PSI (50 bar). It is also used to issue over pressure
warning and trapped high-pressure warning messages. If the pressure display shows
something other than 0 PSI when the system is at 0 PSI, pushing F7 will recalibrate
the transducer.