SECTION 8
ELECTRICAL SYSTEM
Jan 2001
Page 8-3
05114632
8.1.3 Operation
During normal operation, the control panel shows operating messages and the
RUN green light will be lit. After pulling the EMERGENCY STOP and CONTROL
POWER ON pushbutton is pressed:
The control power is turned ON.
The cutting water inlet valve (11) solenoid is powered on and opens. It will
remain on for 2 minutes or until the motor is started, whichever occurs first. If
the 2 minutes elapses before the motor is started, the solenoid must be re-
opened by pressing F6.
The high pressure dump valve (3) is powered on and closes.
NOTE
The high-pressure dump valve will not close if the air supply is OFF.