20 S008769 Rev A
Ngenuity Operator Manual
The table below identifies the various actions of the MAINTENANCE LED depending upon the
state of the scanner:
N
OTE
In the event a self-test failure occurs, contact your local BBH Authorized Service Provider
(ASP). A list of BBH ASPs can be found on our web site at www.bbhscanners.com
.
2.1.1.4 Manual Feed LED
The MANUAL FEED LED indicates whether or not the feed mode has been
changed from the normal/default ADF (Automatic Document Feed) mode to the
Manual mode. When lit, the MANUAL FEED LED is green in color.
The table below identifies the various actions of the MANUAL FEED LED depending upon the
feed mode setting on the scanner (see ”2.1.1.5
Feed Modes” on page 21 for more information):
Scanner State Maintenance LED
System OK; no maintenance currently
required
OFF (not lit)
Maintenance needed (see ”2.2
Ngenuity
Operator Utility” on page 29 for more
information)
SLOW BLINKING
Scanner Busy/Offline; occurs when scanner is
in off-line mode and not capable of scanning
(occurs when scanner is in a special mode
such as ADF Test, during camera calibration,
while downloading firmware, performing an
imprinter cleaning)
FAST BLINKING
Self-test failure; needs service (coincides with
the reminders displayed in the Maintenance
Monitor of the Ngenuity Operator Utility (NOU)
- see ”2.2.2.3
Maintenance Monitor” on
page 35)
STEADY ON
Feed Mode Setting Manual Feed LED
ADF feed mode OFF (not lit)
Manual feed mode STEADY ON