S008769 Rev A 23
Operating Your Scanner
command was issued, only the first document’s image is kept. To scan and save multiple
images, issue a batch scan command.
The scanner will stay in Manual mode until the Operator sets it back to ADF mode, or
reestablishes contact between the scanning application and the scanner.
ASSISTED MANUAL MODE
The Assisted Manual mode operates the same way as the Manual mode, with the exception of
the skimmer being in the down position (see step #2
above). The skimmer in a down position
assists the Operator in feeding the documents into the scanner so that the Operator does not
have to push or feed the documents as far into the scanner’s transport as they would in regular
Manual mode.
TEST FEED MODE
The Test Feed mode is used to test and verify the scanner’s feeding capabilities, as well as to
feed the transport cleaning sheets (see ”5.3.5
Cleaning the Transport” on page 82). It allows the
Operator or service technician to feed documents without having to generate a scan command
from the host PC.
Unlike ADF mode and Manual (Assisted) mode, the Test Feed mode is set or activated from
within the Custom Functions section of the Ngenuity Operator Utility or NOU (see ”2.2.3.3
Custom
Functions” on page 38 for more information) and is only functional when the scanner is set to ADF
mode in the scanning application.
2.1.2 Feeder Table
The next area of the control panel is the Feeder Table. The
Feeder Table section contains two pushbutton switches: DOWN/
SET; and UP. These two pushbutton switches control the feeder
table bottom position for ADF mode, allowing for “continuous”
batch size selection.
How it works...
• With the feeder empty, press and hold the DOWN/SET pushbutton to drive the feeder down-
ward. Release the pushbutton and the table movement stops. This current position becomes
the new bottom table stop. If the DOWN/SET pushbutton is held indefinitely, table movement
stops at the bottom physical limit.
• With the feeder empty, press and hold the UP pushbutton to drive the feeder up. Release the
pushbutton and the feeder movement stops. This position becomes the new bottom table
position.