S008769 Rev A 47
Advanced Features
NOTE
If the scanner’s audio feature has been set to Mute (see ”2.2.3.4 Audio” on page 38), the
multifeed alarm that occurs with the Notify and Stop options will not be audible to the
Operator.
3.2.1.2 Enable Sensors
The Enable Sensors control allows the Operator to
enable or disable three individual sensors that, when
enabled, assist in triggering a multifeed alarm. The
three sensors are: Left, Center, and Right.
One or more of these three sensors can be disabled at any given time; however, if all three are
disabled, the Enable Sensors control grays out (becomes inactive) and the Multifeed Mode
control (see ”3.2.1.1
Multifeed Mode” on page 46) automatically sets itself to Off.
3.2.1.3 Ignore by Size
The Ignore by Size control allows the Operator to set
the maximum size of a multifeed that will NOT trigger a
multifeed error when scanning.
This is used to scan documents with labels (often
barcodes) or stickers (mailing labels), documents with
taped photographs or receipts - all while still having
multifeed detection active.
The Ignore by Size parameter can be set in inches or millimeters (mm), with a range of 1.0 to 25.5
inches (25-647 mm). The default setting for this control is 1.0 inch (25 mm).