S008769 Rev A 69
Maintenance
The cameras’ glass covers are part of the Optics group (see ”5.3.2 Optics” on page 68 above).
W
ARNING
Never attempt to remove the glass flat from its frame. Doing so can cause the glass flat to
crack or break and could cause injury to the person holding it.
WARNING
Before performing any maintenance procedures, power OFF the scanner.
WARNING
Before performing any maintenance procedures on the scanner, remove all jewelry or any
items from hands or wrists that could become caught on internal scanner components.
CLEANING GLASS FLATS
Over time the glass flats will become dirty with smudges and/or paper dust which can case
streaks in images, reduced OCR/ICR/Barcode recognition rates, blurred images, etc.
To prevent these problems, BBH recommends cleaning the glass flats every 50,000 pages fed or
as needed. Different document types, the condition of the documents being scanned, and the
volume of scanning may require more frequent cleanings.
For best results, remove the glass flats and clean both sides of each.
Item(s) Needed
Roller and Glass Cleaner
Lint Free Cloth
C
AUTION
Never spray the Roller and Glass Cleaner into the scanner.
To clean the bottom (back page) glass flat, perform the following:
1. Power OFF the scanner (see 1.4.2 Scanner Back,
Power Switch” on page 11)
2. Open the scanner’s transport cover (see 1.4.1 Scanner Front,
Transport Cover” on page 7
and
Transport Cover Release Levers” on page 7)
3. Remove the bottom (back page) glass flat