68 S008769 Rev A
Ngenuity Operator Manual
8. After replacing the separator roller, replace the skimmer roller tires (4 total) (see 5.3.1 Feed
Rollers, “
Replacing Tires” on page 63))
9. Once the separator roller and all four skimmer
roller tires have been replaced, reset the
maintenance reminder for replacing the Feed
Rollers located in the Maintenance Monitor
section of the NOU’s Home Screen
- With the NOU active and communicating with
the scanner (see ”2.2
Ngenuity Operator
Utility” on page 29), click on the Replace
hyperlink associated with “Replace Feed
Rollers” in the Maintenance monitor of the
Home screen
- A confirmation dialog window will display.
Confirm the feed rollers have been replaced
by clicking the YES button. This will reset the
reminder to begin monitoring for the next
required maintenance session
5.3.2 Optics
Glass Flats, Cameras’ Glass Covers, and Sensors are the scanner components that make up the
group known as the “Optics” for maintenance purposes. BBH recommends that for optimal
performance, the scanner’s Optics should be cleaned as a group, i.e. at the same time. If one
component is to be cleaned, then every component that makes up the scanner’s Optics should be
as well.
After all of the components that make up the Optics are cleaned, the Optic’s maintenance
reminder in the NOU needs to be reset (see ”2.2
Ngenuity Operator Utility” on page 29) so future
reminders will display (including the MAINTENANCE LED on the scanner’s control panel).
Instructions on how to do this accompany the instructions for each of the Optics’ maintenance
procedures.
C
AUTION
For Ngenuity scanners, the label ‘Optics’ does NOT include lamps. The lamps (LEDs) on
Ngenuity scanners should NOT be cleaned or wiped with any type of wipes and/or solvent.
5.3.2.1 Glass Flats
There are two glass flats in the Ngenuity scanner; one located in the bottom (back page) transport
tray and one in the top (front page) transport tray. They are securely set inside black, plastic
frames. When removing a glass flat for cleaning or replacement, the entire assembly (glass flat
and frame) are removed and replaced as one piece.