46 S008769 Rev A
Ngenuity Operator Manual
3.2.1 Multifeed Screen
The Advanced Properties Multifeed screen contains
three sets of controls: Multifeed Mode; Enable
Sensors; Ignore by Size.
3.2.1.1 Multifeed Mode
The Multifeed Mode control determines the
response of the scanner if a multifeed occurs. There
are three available options: Off; Notify; and Stop.
• Off - No multifeed detection occurs. Scanning
continues and all scanned images are retained
• Notify - Scanner responds to the occurrence of
a multifeed by sounding an audible alarm and
momentarily lighting the MULTIFEED LED on the scanner’s control panel (see
”2.1.4.5
Multifeed LED & MF Ignore Pushbutton” on page 26); however, scanning continues,
the multifeed is ignored, and the image of the multifeed document is retained
• Stop - Upon the detection of a multifeed, the scanner sounds an audible alarm, the
MULTIFEED LED on the scanner’s control panel lights steady (see ”2.1.4.5
Multifeed LED &
MF Ignore Pushbutton” on page 26), and the scanner’s transport stops. The Operator then
has two choices:
Delete the Multifeed Image
1. Using the Custom Function pushbutton on the control panel that is set to “Page Eject”,
eject the multifeed document from the transport (refer to
”2.2.3.3 Custom Functions” on
page 38 for more information on Custom Functions)
2. Correct whatever it was that caused the multifeed and place the multifeed document back
in the feeder on the top of the batch of documents to be scanned
3. Press the CLEAR/RESTART pushbutton on the scanner’s control panel to automatically
restart scanning
Retain the Multifeed Image
- Press the MF IGNORE pushbutton on the scanner’s control panel. After a couple of sec-
onds, the scanner will automatically eject the multifeed document and continue scanning
documents, retaining the multifeed image
N
OTE
For information on using Preemptive Multifeed Ignore, go to “Preemptive Multifeed Ignore"
under ”2.1.4.5