4 — PROGRAMMABLE PARAMETERS
Curtis Model 3401T – August 2022 Return to TOC
pg. 42
PI Menu
e 3401T has a proportional/integral current controller, which is congured by the parameters on
the PI menu.
PI MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES DATA SIZE
ACCESS LEVEL
DEFAULT VALUE DESCRIPTION
Kp
0x66B0:00
1–100%
20–2048
16-bit OEM Dealer
8%
Species the proportional gain factor of the current
PI controller.
Ki
0x66C0:00
1–100%
20–2048
16-bit OEM Dealer
20%
Species the integral gain factor of the current PI
controller.
MISC MENU
e following table describes the parameters on the Misc menu.
MISC MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES DATA SIZE
ACCESS LEVEL
DEFAULT VALUE DESCRIPTION
Mode Saving
0x4800:00
Off/On
0–1
32-bit Field Intermediate
On
Species whether the speed mode is saved when
the 3401T is powered down. On indicates that the
speed mode is saved.
PIN Code Source
0x3102:00
Enumerated
0–2
32-bit Field Intermediate
None
Species whether a password is required when the
3401T is powered up and whether the 3401T or the
ECS is used to enter the password:
0 = None. A password is not required.
1 = Internal. The 3401T is used.
2 = External. The ECS is used. This value can be
selected only when the 3401T and the ECS
are in the operational NMT state and the ECS
node ID is specied.
HYD Controller Enable
0x6900:00
Off/On
0–1
32-bit Field Intermediate
On
Species whether fault codes for the hydraulic
controller are displayed. On = displayed.
Programmer Protocol
0x6902:00
Enumerated
0–1
32-bit Field Intermediate
ESP/SP
Species the protocol used for Curtis
programming devices:
0 = ESP/SP. For the serial version of the 1313
handheld programmer.
1 = CIT. For the Curtis Integrated Toolkit™ (CIT)
and the CANbus version of the 1313
handheld programmer.
Vehicle Config
0x6909:00
1–65535
1–65535
32-bit OEM Dealer
1
Species the type of vehicle that is being used with
the 3401T. The correct value must be entered in
order to view fault names.
If you are not sure of the correct value, contact your
Curtis distributor or the Curtis sales and support
ofce in your region.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler CURTIS 3401T and is the answer not in the manual?

Kohler CURTIS 3401T Specifications

Power IconPower
nominal voltage12–96 VDC
minimum voltage8 VDC
maximum voltage120 VDC
keyswitch on current33–207mA
keyswitch off current25–112mA
LCD heater on current566–801mA
Operating Environment IconOperating Environment
operating temperature with LCD heater–40°C to +70°C
operating temperature without LCD heater–20°C to +70°C
storage temperature–40°C to +85°C
Weight and Dimensions IconWeight and Dimensions
dimensions160 x 102 x 49.7 mm