12.6.4 Installation and operating conditions
The motors may be used only in ambient temepratures up to 50 °C.
If the front flange is coated, the tolerance class N is not guaranteed.
Motors with flanges without wash-outdown coating: The flange surface must be protected
by suitable assembly against the influence by cleaning agents.
12.6.5 Cleaning plan
Recommended cleaning plan (short form) with tested cleaning agents:
Flushing with water (40 °... 50 °C)
Flushing with low pressure. From top to bottom in the direction of the drain. Clean the
drain.
Foam cleaning
Foaming from top to bottom.
Alkaline: P3-topactive LA or P3-topax 66 (2-5%, 15 min daily)
Acid: P3-topax 56 (2%, if necessary 15 min)
Temperature: cold up to 40 °C
Disinfection
Spraying with wayer (40 °... 50 °C) with low pressure. From top to bottom.
Spray disinfection: P3-topax 91 (1-2%, if necessary 30-60 min)
Foam disinfection: P3-topactiv DES (1-3%, if necessary 10-30 min)
English - 48 Servomotors AKM
Technical Description 04/2013 Kollmorgen
ENGLISH