2.3.9. Take-off speed Speed at
which the lower clamping roller rotates after the dwell time has elapsed.
Seal seam strength of the still hot/warm seal seam
2.3.16. Cold seam strength / final seam strength (cold tack)
2.3.10. Seam separation speed Speed
at which the created seam separates.
2.3.8. Residence time
Duration from the end of the seal to the sample tension or until the start of the tearing force.
2.3.14. Tensile force threshold Limit
value for the starting point of the force/time curve recording.
With the laboratory master, the dwell time can be extended to measure the cold seam strength.
2.3.15. Warmnahtfestigkeit (Hot-Tack)
Seal seam strength tester Labormaster HCT 3000
2.3.13. Seal Strength Force
necessary to separate a seal. A distinction is made between tearing force: force that
must be applied in the first few millimeters.
Operating instructions and technical description
.
Page - 14 -
Separation force: Average
force Maximum force: Maximum force achieved during the test (peak).
2.3.11. Sealing jaws
Heated holder for the sealing rails.
Seal seam strength of the seal seam cooled to room temperature
2.3.12. Sealing rails
Metal rails with the actual sealing contact surface (smooth or profiled, uncoated or with PTFE coating)
D-73262 Reichenbach/Fils
E-Mail: sales@kopp-online.de
http://www.kopp-online.de
Ulmer Straße 51 53
Willi Kopp e. K
Phone +49.7153.9510-0 Fax
+49.7153.9510-100
Packaging systems
owner Ludwig P. Goller
Subject to errors and technical changes!
Labormaster Version 2.6.3 SW 2.2 from 03/2016 Page 14 of 82, March 1, 2016