Page #60 background image
Sealing bars and sealing jaws
6.2.
Labormaster Version 2.6.3 SW 2.2 from 03/2016 Page 60 of 82, March 1, 2016
Subject to errors and technical changes!
After this parallelism test, if you notice an offset between the upper and lower sealing jaws, compensate for this using
the fastening screws of the upper sealing jaw:
Finger protection (“Finger protection” p. 12). The device may not be used without this finger protection
- Sealing time: 1.5 s
The upper sealing jaw, which has been manually pressed down, immediately moves up!
Operating instructions and technical description
600 N
Only have it carried out by trained personnel!
5. Turn the power switch back on, the air pressure will automatically reset.
Check the parallelism of the sealing surfaces with the following parameter setting:
If parallelism is no longer possible, contact the service department of the manufacturer.
Page - 60 -
2. After opening the sealing jaws, remove the paper:
3. Loosen the hexagon screws.
operate!
1. Place two carbon paper sheets with carbon paper inside between the sealing bars
1. Switch off the mains disconnection device (main switch), air pressure is automatically set to zero.
- Sealing temperature: 140°C
Seal seam strength tester Labormaster HCT 3000
6.2.2.
Be sure to always install it after any service work has been carried out
Danger:
- Sealing power:
Correct the offset of the sealing jaws
The visible impression shows you the parallelism of the sealing surfaces to one another.
6.2.1.
4. Align the sealing jaw and tighten the screws.
2. Manually press down the upper sealing jaw.
Check sealing surface parallelism
and carry out a sealing.
Fax +49.7153.9510-100
E-Mail: sales@kopp-online.de
Ulmer Straße 51 53
Willi Kopp e. K
http://www.kopp-online.de
D-73262 Reichenbach/Fils
Packaging systems
Phone +49.7153.9510-0
Inh. Ludwig P. Goals
Machine Translated by Google

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kopp Labormaster HCT 3000 and is the answer not in the manual?

Kopp Labormaster HCT 3000 Specifications

General IconGeneral
BrandKopp
ModelLabormaster HCT 3000
CategoryLaboratory Equipment
LanguageEnglish