Auto Power Off .................................................... Disable, 30 Minutes, 4 Hours
Sets whether the auto power-off function is enabled or disabled.
When the auto power-off function is enabled, the power automatically turns off when a certain length
of time has elapsed since the pads were played or the unit was operated. (The default setting is
“4hours”.)
Use the dial if you wish to change this to a different setting.
Note:
The auto power-off count will be canceled under any of the following conditions:
When the panel is operated, a pad is triggered, the looper or a recorded SAMPLE is played back, the metronome
is used, SysEx data is received via USB MIDI, or when an import/export is executed that includes SAMPLE data.
Setup / PAD Trigger
This screen lets you configure the trigger settings for each of the 15 pads built into the MPS-10.
PAD# ................................................................................1...10 / A,B,C,D / Pedal
Specifies the number of the pad for which you want to configure the trigger settings.
Note:
You can change the pad number by striking the pads.
Sensitivity...................................................................................................0...100
Adjusts the trigger sensitivity.
Threshold.....................................................................................................0...100
Adjusts the minimum striking force required to make the pad react. This has no effect on the pedal.
Retrigger .....................................................................................................0...100
This makes adjustments to improve retriggering.
Note:
Increase the retriggering value to avoid pads sounding two notes when played only once. Note that this will
make the pad less able to detect drum rolls. When you lower this value, you will be able to play intricate flams,
but the pad will be more likely to sound twice with one stroke.
XTalk Cancel............................................................................................... On, Off
You can configure the MPS-10 to cancel out the resonance from other pads when a pad sounds.
Turn this on to reduce resonance. This is enabled when used with external triggers (A–D).
Note:
When this is set to “On,” striking two pads at the same time may be considered as resonance, and the sound
from one of the pads may not be heard as a result. If this happens, turn the setting off and check again.
Setup / Audio In & Out
Use this screen to edit the parameters related to audio input/output.
Tip:
There are three “Audio In & Out” settings: “Input”, “Output” and “Out Routing”. Use the METRONOME knob to
switch between setting pages.

Table of Contents

Other manuals for Korg MPS-10

Related product manuals