Installation
1. De-energise the home network. Ch. 4.3
2. Fit ripple control receiver in control cabinet or power
distributor.
3. Correctly route the communication cable from the
inverter to the control cabinet and connect to ripple
control receiver following wiring diagram provided by
manufacturer.
4. Connect communication cable in inverter to
terminal for ripple control receiver (torque: 0.2 Nm)
Fig. 30, It. 2
H
The ripple control receiver is connected.
More information about the configuration
Ch. 8.
DANGER
RISK OF DEATH DUE TO ELECTRI-
CAL SHOCK AND DISCHARGE!
De-energise device and secure
against being switched on again.
Ch. 4.3
INFO
The communication cable is subject
to the following requirements:
n Wire cross-section of
0.34 - 1.5 mm
2
(rigid)
0.34 - 1.0 mm
2
(flexible)
n Max. length 30 m
n Length of stripped insulation
4.5-5.5 mm