© 2018 KOSTAL Solar Electric GmbH
Operation and operating the device
Public grid menu (AC side)
Current AC power Shows the voltage (U), current (I) and power (P)
per phase, which is being fed into the public grid.
Yield overview Shows the power per day, month, year, total in Wh, kWh or
MWh, which has been fed into the public grid.
Grid parameter Shows the current grid frequency, the set reactive power
(cosphi), the current power and, if configured, the set power
curtailment, e.g. to 70%.
Home consumption menu
Current consumption Shows the current consumption in the house and the source
from which it is being covered.
Daily consumption Shows the daily consumption in the house and the source
from which it has been covered.
Monthly consumption Shows the monthly consumption in the house and the source
from which it has been covered.
Degree of self-suciency Degree of self-suciency shows self-consumption in relation
to home consumption. This states the percentage of energy
consumed in the building that has been covered by the PV/
battery energy generated.
Self-consumption rate Self-consumption rate shows the self-consumption in relation
to the total power generated by the inverter. This states the