63 / 127Issued: 18.06.2015 Version: Spez KR QUANTEC extra V6
4 Technical data
4.7.6.4 Stopping distances and stopping times for STOP 1, axis 3 
4.7.7 Stopping distances and times, KR 150 R2700 extra C
4.7.7.1 Stopping distances and stopping times for STOP 0, axis 1 to axis 3
The table shows the stopping distances and stopping times after a STOP 0 
(category 0 stop) is triggered. The values refer to the following configuration:
 Extension l = 100%
 Program override POV = 100%
 Mass m = maximum load (rated load + supplementary load on arm)
Fig. 4-45: Stopping distances for STOP 1, axis 3
Fig. 4-46: Stopping times for STOP 1, axis 3
Stopping distance (°) Stopping time (s)
Axis 1 87.01 1.28
Axis 2 48.94 0.69
Axis 3 44.82 0.54