2M4/2M5/2M6/2M7
1-4-34
(2-5) U010XX error code table: G3 transmission
Error code Description
U01000 An FTT signal was received for a set number of times after TCF signal transmission at
2400 bps. Or, an RTN signal was received in response to a Q signal (excluding EOP)
after transmission at 2400 bps.
U01001 Function of the unit differs from that indicated by a DIS signal.
U01010 No relevant signal was received after transmission of a DNL (MPS or EOM) signal, and
the preset number of command retransfers was exceeded (between units of our make).
U01011 No relevant signal was received after transmission of a DCS, TCF signal, and the preset
number of command retransfers was exceeded.
U01012 No relevant signal was received after transmission of an NSS1, NSS2 (TCF) signal, and
the preset number of command retransfers was exceeded (between units of our make).
U01013 No relevant signal was received after transmission of an NSS3, TCF signal, and the pre-
set number of command retransfers was exceeded (between units of our make).
U01014 No relevant signal was received after transmission of an MPS signal, and the preset
number of command retransfers was exceeded.
U01015 No relevant signal was received after transmission of an EOM signal, and the preset
number of command retransfers was exceeded.
U01016 An MCF signal was received but no DIS signal was received after transmission of an
EOM signal, and T1 timeout was detected.
U01017 No relevant signal was received after transmission of an EOP signal, and the preset
number of command retransfers was exceeded.
U01018 No relevant signal was received after transmission of a PRI-EOP signal, and the preset
number of command retransfers was exceeded.
U01019 No relevant signal was received after transmission of a CNC signal, and the preset num-
ber of command retransfers was exceeded (between units of our make).
U01020 No relevant signal was received after transmission of a CTC signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01021 No relevant signal was received after transmission of an EOR.Q signal, and the preset
number of command retransfers was exceeded (ECM).
U01022 No relevant signal was received after transmission of an RR signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01023 No relevant signal was received after transmission of a PSS.NULL signal, and the preset
number of command retransfers was exceeded (ECM).
U01024 No relevant signal was received after transmission of a PSS.MPS signal, and the preset
number of command retransfers was exceeded (ECM).
U01025 No relevant signal was received after transmission of a PPS.EOM signal, and the preset
number of command retransfers was exceeded (ECM).
U01026 No relevant signal was received after transmission of a PPS.EOP signal, and the preset
number of command retransfers was exceeded (ECM).
U01027 No relevant signal was received after transmission of a PPS.PRI-EOP signal, and the
preset number of command retransfers was exceeded (ECM).
U01028 T5 time-out was detected during ECM transmission (ECM).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kyocera ECOSYS FS-1020MFP and is the answer not in the manual?

Kyocera ECOSYS FS-1020MFP Specifications

General IconGeneral
Print TechnologyLaser
Print Resolution600 x 600 dpi
Scan Resolution600 x 600 dpi
Paper Capacity250 sheets
ConnectivityUSB 2.0
Monthly Duty Cycle20, 000 pages
Time to First Page8.5 seconds
Duplex Print ModeManual
Scan TypeFlatbed
Output Capacity100 sheets
Maximum Paper SizeA4
FunctionsPrint, Copy, Scan
Memory32 MB
Print Speed20 ppm
Copy Speed20 pages per minute
Maximum Scan Area8.5 x 14 inches
Fax Transmission SpeedNot supported