2M4/2M5/2M6/2M7-1
1-5-30
1-5-7 Others
(1) Detaching and refitting the Main motor unit
Procedure
1. Remove the The scanner unit (see
page 1-5-10).
2. Remove the left cover (see page 1-5-6).
3. Remove the two screws and pull out the
fuser unit halfway out.
Figure 1-5-46
4. Unhook the four hooks and then
remove the upper LSU cover.
Figure 1-5-47
Fuser unit
Screw
Screw
Upper LSU cover
Hook