2NL/2P8
1-2-13
[Set cassette heater control (maintenance item U327)]
1. Enter the maintenance mode by entering 10871087 using the numeric keys.
2. Enter 327 using the numeric keys and press the start key.
3. Select [On].
4. Press the start key. The setting is set.
5. Press the stop key to exit.
[Setrting the delivery date (maintenance item U278)]
1. Enter 278 using the numeric keys and press the start key.
2. Select [Today].
3. Press the start key. The delivery date is set.
4. Press the stop key to exit.
[Output an own-status report (maintenance item U000)]
1. Enter 000 using the numeric keys and press the start key.
2. Select Maintenance and press the start key to output a list of the current
settings of the maintenance items.
3. Press the stop key to exit.
[Clearing the counter (maintenance item U927)]
1. Enter 927 using the numeric keys and press the start key.
2. Select [Excute].
3. Press the start key. The counter is cleared.
4. Press the stop key to exit.
1. Enter “001” using the numeric keys and press the start key.
1. Select [Report Print] to print a user setting list.
1. Place an original and make test copies.
Print out a user setting list
Installation is completed.