2NL/2P8-4
2-4-6
(4) Repetitive defects gauge
* : The repetitive marks interval may vary depending on operating conditions.
First occurrence of defect
39.3 mm/1
9/16” Developing roller
37.5 mm/1
1/2” Chager roller
94 mm/3
11/16” Drum
46.5 mm/1
13/16” Right/Left registration roller
78.5 mm/3
1/16” Heat roller/Press roller
49.5 mm/1 15/16” Transfer roller