2NL/2P8
2-3-11
Connector Pin Signal I/O Voltage Description
YC1
1 EJE_SOL_PU
LL
O 0/24 V DC FSSOL: On(Pressurizing)/Off
Connected to
feedshift
solenoid
2 24VF2 O 24 V DC 24 V DC power output to FSSOL
3 EJE_SOL_RE
TURN
O 0/24 V DC FSSOL: On(Release)/Off
YC2
1 24V4 O 24 V DC 24 V DC power output to EFM
Connected to
eject fan
motor
2 EJECT_FAN_
REM
O 0/3.3 V DC EFM: On/Off
YC3
1 EJECT A O 0/24 V DC(pulse) EM drive control signal
Connected to
eject
motor,job
paper full
sensor,
paper full
sensor and
eject sensor
2 EJECT B O 0/24 V DC(pulse) EM drive control signal
3 EJECT /A O 0/24 V DC(pulse) EM drive control signal
4 EJECT /B O 0/24 V DC(pulse) EM drive control signal
5 3.3VLED O 3.3 V DC 3.3 V DC power output to JPFS
6 GND - - Ground
7 EJE_FULL_U
PPER
I 0/3.3 V DC JPFS: On/Off
8 3.3VLED O 3.3 V DC 3.3 V DC power output to PFS
9 GND - - Ground
10 EJE_FULL_D
OWNER
I 0/3.3 V DC PFS: On/Off
11 3.3VLED O 3.3 V DC 3.3 V DC power output to ES
12 GND - - Ground
13 FSR_SENS I 0/3.3 V DC ES: On/Off
YC4
1 Vout I 0/3.3 V DC JEPS: On/Off
Connected to
job separa-
tor eject sen-
sor
2 GND - - Ground
YC5
1 3.3V4 O 3.3 V DC 3.3 V DC power output to FTH
Connected to
fuser
thermistor1,
2
2 GND - - Ground
3 TH1 I Analog FTH Detection voltage (Edge)
4 TH2 I Analog FTH Detection voltage (Center)
YC6
1 HUM_DATA I Analog TEMS detection voltage (Humidity)
Connected to
temperature
sensor
2 HUM_CLK2 O 0/3.3 V DC(pulse) TEMS clock sijgnal
3 HUM_CLK1 O 0/3.3 V DC(pulse) TEMS clock sijgnal
4 TEM_DATA I Analog TEMS detection voltage (Temperature)
5 GND - - Ground