PLMNL0232 REV. H Effective Date: 01/14/19 66 FiberCUT
®
2D Operation Manual
15 Appendix H – Maintenance
After performing any
maintenance
Inspect and replace any worn or damaged hoses.
See Section 2.3 for more details.
Inspect and adjust as needed according to Section 2.4.
Lubricate the o-rings. See Section 2.4 for more details.
Calibrate according to Section 3
Calibrate the pressure sensor according to Section 4.4.4.
Monthly or more often if
needed
Clean the entire outside of the head, according to Section 5.1.
Inspect and replace as needed, according to Section 5.2.
Replace the lower cover glass (PLLCG0060) according to
Section 5.3.1
Replace the lower seal (PLMSR0030) according to
Section 5.3.1
Consult a service specialist, proceed as directed
EVERY time you replace the
cover glass
Replace the upper cover glass and seal according to
Section 5.3.2.
Consult a service specialist, proceed as directed
Replace the focus lens cartridge according to Section 5.6 or
Section 5.7.
Consult a service specialist, proceed as directed
Replace the collimator lens cartridge according to Section 5.9