4.Iftheadapterwasmovedtoadifferentslotandtheerrordidnotrecur,verifythatthisisnota
systemlimitation.Thenreplacethesystemboard.Also,ifthisisnottheinitialinstallationandthe
errorpersistsafteradapterreplacement,replacethesystemboard.
•I.2018003[I.2018003]
Explanation:AbadoptionROMchecksumwasdetectedforthedevicefoundatBus%Device%
Function%.TheVendorIDforthedeviceis%andtheDeviceIDis%.ROMCHECKSUMERROR
Severity
Error
UserResponse
Completethefollowingsteps:
1.IfthisPCIedeviceand/oranyattachedcableswererecentlyinstalled,moved,servicedor
upgraded,reseattheadapterandanyattachedcables.
2.Movetheadaptertoadifferentsystemslot,ifavailable.
3.CheckIBMsupportsiteforanyapplicableservicebulletinorUEFIoradapterfirmwareupdate
thatappliestothiserror.NOTE:ItmaybenecessarytoconfigureslottoGen1ortouse
specialutilitysoftwaresothatadapterfirmwarecanbeupgraded.Gen1/Gen2settingscanbe
configuredviaF1Setup->SystemSettings->DevicesandI/OPorts->PCIeGen1/Gen2/Gen3
SpeedSelection,ortheASUUtility.
4.Replacetheadapter.
•I.3808004[I.3808004]
Explanation:TheIMMSystemEventlog(SEL)isfull.IPMISystemEventLogisFull
Severity
Info
UserResponse
Completethefollowingsteps:
1.UsetheIMMWebInterfacetocleartheeventlog.
2.IfIMMcommunicationisunavailable,useF1SetuptoaccessSystemEventLogsMenuand
ChooseClearIMMSystemEventLogandRestartServer.
•I.3818001[I.3818001]
Explanation:Thefirmwareimagecapsulesignatureforthecurrentlybootedflashbankisinvalid.Current
BankCRTMCapsuleUpdateSignatureInvalid
Severity
Info
UserResponse
Completethefollowingsteps:
1.Rebootthesystem.WillcomeuponbackupUEFIimage.UpdatetheprimaryUEFIimage.
2.Iferrordoesnotpersistnoadditionalrecoveryactionisrequired.
AppendixB.UEFI/POSTdiagnosticcodes1035