Severity
Error
UserResponse
Completethefollowingsteps:
1.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatappliestothis
memoryerror.
2.Ifthenodehasrecentlybeeninstalled,moved,serviced,orupgraded,verifythattheDIMM
isproperlyseatedandvisuallyverifythatthereisnoforeignmaterialinanyDIMMconnector
onthatmemorychannel.Ifeitheroftheseconditionsisfound,correctandretrywiththesame
DIMM.(Note:EventLogmaycontainarecent580A4eventdenotingdetectedchangeinDIMM
populationthatcouldberelatedtothisproblem.)
3.IfnoproblemisobservedontheDIMMconnectorsandtheproblempersists,replacetheDIMM
identifiedbyLightPathand/oreventlogentry.
4.Ifproblemre-occursonthesameDIMMconnector,swaptheotherDIMMsonthesamememory
channelacrosschannelsoneatatimetoadifferentmemorychannelorProcessor.(check
serviceinformationforthisproduct/Installguideforpopulationrequirementsforsparing/paring
modes).IfproblemfollowsamovedDIMMtoadifferentmemorychannel,replacethatDIMM.
5.(Trainedservicetechnicianonly)RemoveaffectedProcessorandinspectProcessorsocketpins
fordamagedormis-alignedpins.Ifdamageisfound,orthisisanupgradeProcessor,replace
thesystemboard.IftherearemultipleProcessor’s,swapProcessor’stomoveaffectedProcesor
toanotherProcessorsocketandretry.IfproblemfollowstheaffectedProcessor(orthereisonly
oneProcessor),replacetheaffectedProcessor.
6.(Trainedtechnicianonly)IfproblemstayswiththeoriginalDIMMconnector,re-inspectDIMM
connectorforforeignmaterialandremove,iffound.Ifconnectorisdamaged,replacesystem
board
•S.51006[S.51006]
Explanation:Amemorymismatchhasbeendetected.Pleaseverifythatthememoryconfigurationis
valid.OneorMoreMismatchedDIMMsDetected
Severity
Error
UserResponse
Completethefollowingsteps:
1.Couldfollowanuncorrectablememoryerrororfailedmemorytest.Checkthelogandservice
thateventfirst.DIMMsdisabledbyothererrorsoractionscouldcausethisevent.
2.VerifythattheDIMMsareinstalledinthecorrectpopulationsequence.
3.Disablememorymirroringandsparing.Ifthisactioneliminatesthemismatch,checktheIBM
Supportsiteforinformationrelatedtothisproblem.
4.UpdateUEFIfirmware.
5.ReplacetheDIMM.
6.Replacetheprocessor.
•S.51009[S.51009]
Explanation:Nosystemmemoryhasbeendetected.NoMemoryDetected
1044LenovoSystemx3650M5InstallationandServiceGuide