Severity
Error
UserResponse
Completethefollowingsteps:
1.Ifanymemoryerrorsareloggedotherthanthisone,takeactionsindicatedforthosecodesfirst.
2.Ifnoothermemorydiagnosticcodesappearinthelogs,verifythatallDIMMconnectorsare
enabledusingtheSetuputilityortheAdvancedSettingsUtility(ASU).
3.Iftheproblemremains,shutdownandremovenodefromchassisandphysicallyverifythatone
ormoreDIMMsareinstalledandthatallDIMMsareinstalledinthecorrectpopulationsequence.
4.IfDIMMsarepresentandproperlyinstalled,checkforanylitDIMM-connectorLEDs,andif
found,reseatthoseDIMMs.
5.Reinstallnodeinchassis,poweronnode,thenchecklogsformemorydiagnosticcodes.
6.(Trainedtechnicianonly)Iftheproblemremains,replacetheprocessor.
7.(Trainedtechnicianonly)Iftheproblemremains,replacethesystemboard.
S.58008[S.58008]
Explanation:ADIMMhasfailedthePOSTmemorytest.DIMMFailedMemoryTest
Severity
Error
UserResponse
Completethefollowingsteps:
1.YoumustAC-cyclethesystemtore-enabletheaffectedDIMMconnectororre-enablemanually
usingtheSetuputility.
2.Ifthecomputenodehasbeenrecentlyinstalled,serviced,moved,orupgraded,checktoensure
thatDIMMsarefirmlyseatedandthatnoforeignmaterialcanbeseenintheDIMMconnector.
Ifeitherconditionisobserved,correctandretrywiththesameDIMM.(Note:TheeventLog
mightcontainarecent00580A4eventdenotingdetectedchangeinDIMMpopulationthat
couldberelatedtothisproblem.)
3.Ifproblempersists,replacetheDIMMidentifiedbyLightPathand/oreventlogentry.
4.IfproblemrecursonthesameDIMMconnector,swaptheotherDIMMsonthesamememory
channelacrosschannelsoneatatimetoadifferentmemorychannelorprocessor.Ifproblem
followsamovedDIMMtoadifferentmemorychannel,replacethatDIMM.
5.ChecktheIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatapplies
tothismemoryerror.
6.(Trainedservicetechnicianonly)RemoveaffectedProcessorandinspectProcessorsocketpins
fordamagedormis-alignedpins.Ifdamageisfound,orthisisanupgradeProcessor,replace
thesystemboard.IftherearemultipleProcessor’s,swapProcessorstomoveaffectedProcesor
toanotherProcessorsocketandretry.IfproblemfollowstheaffectedProcessor(orthereisonly
oneProcessor),replacetheaffectedProcessor.
7.IfproblemstayswiththeoriginalDIMMconnector,re-inspectDIMMconnectorforforeign
materialandremove,iffound.Ifconnectorisdamaged,replacesystemboard