Important codes for quick commissioning
8
Commissioning
8.6
L
8.6-6
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0148*
s
Motor parameter
identification
0
0 Ready
Only when the motor is cold!
1. Inhibit controller , wait until drive is in
standstill
2. Enter the correct motor data under
^ 10.9-1
1 Start identification
• V/f-rated frequency (C0015), slip
compensation (C0021) and motor stato r
inductivity (C0092) a re calculated and saved.
• The motor stator resistance (C0084) = total
resistance of motor cable and motor is
measured and saved
,
,
,
,
(see motor nameplate).
3. C0148 = set 1 by
v
4. Enable controller
The identification
–starts,
c gets out
– the motor makes a high-pitched tone,
but does not rotate!
– takes approx. 30 s
– is completed when
c is on again
5. Controller inhibit
C0517*
v
User menu
• After mains switching or when using the
function
g the code from C0517/1
^ 10.18-1
1 Memory 1 50 C0050 Output frequenc y (MCTRL1-NOUT)
will be displayed.
2 Memory 2 34 C0034 Analog setpoint selection range
•
n
enze se
ng,
e user menu con
a
ns
the most im
ortant codes for settin
u
3 Memory 3 7 C0007 Fixed configuration - digital input signals
the control mode ”V/f characteristic
4 Memory 4 10 C0010 Minimum output frequency
control with linear characteristic”
5 Memory 5 11 C0011 Maximum output frequency
• When the password protection is
6 Memory 6 12 C0012 Acceleration time main setpoint
ac
va
e
,on
y
eco
es en
ere
un
er
C0517 are freel
accessible.
7 Memory 7 13 C0013 Deceleration time main setpoint
.
• Enter the required code numbers in the
8 Memory 8 15 C0015 V/f rated frequency
subcodes.
9 Memory 9 16 C0016 U
min
boost
Codes, which are on ly active when
10 Memory 10 2 C0002 Parameter set transf er
e
ng use
oge
er w
an
lication-I
O
cannot be entered!